Room to move
The smallest hole is at least as large as the largest shaft. Minimum clearance may be zero.
TRY H7/g6THE ENGINEERING WORKBENCH
Hole and shaft limits, without the table hunting.
Find your fit and see exactly where it lands.
ONE BASIC SIZE.
TWO TOLERANCE ZONES.
A CLEAR ANSWER.
YOUR FIT
Hole ShaftVertical scale proportional to deviation
| Feature | Lower dev. | Upper dev. | Min. size | Max. size |
|---|
Loading calculator…
READ THE RESULT
The fit describes the possible gap between the hole and shaft at their size limits.
The smallest hole is at least as large as the largest shaft. Minimum clearance may be zero.
TRY H7/g6Either clearance or interference is possible, depending on the actual sizes of the two parts.
TRY H7/k6The smallest shaft is at least as large as the largest hole. Assembly conditions need separate assessment.
TRY H7/p6THE NOTATION
H7 specifies the hole; g6 specifies the shaft. The letter locates the tolerance zone relative to the basic size. The number is the IT grade, which sets the zone width.
A hole-basis fit uses an H hole with zero lower deviation. A shaft-basis fit uses an h shaft with zero upper deviation.
A WORKED EXAMPLE
See the hole and shaft limits at 20 mm and 50 mm, learn how to calculate the gap, and compare H7/g6 with H7/h6.
KNOW YOUR BOUNDARIES
This calculator implements a selected metric subset: basic sizes 1–500 mm, grades IT5–IT13, and the D, E, F, G, H, JS, K, M, N, P, R and S zones and their shaft equivalents. Other classes are not offered. For N9–N13 holes, basic size must be greater than 1 mm.
Calculation references: ISO 286-1:2010 and ISO 286-2:2010. This is an independent implementation, not an ISO publication or certification.
Limits describe dimensional fits only. Surface texture, temperature, material, form, assembly force and functional suitability need separate engineering assessment.
Minimum signed clearance = minimum hole size − maximum shaft size. Maximum signed clearance = maximum hole size − minimum shaft size. Negative signed clearance means interference. For an interference fit, the displayed interference magnitudes are positive.
This version uses metric ISO classes only. Converting units does not turn an ISO fit into an ANSI/ASME B4.1 fit. An inch-fit calculator and cross-standard index are outside this version.
ISO tolerances use size intervals. An upper interval boundary belongs to that interval: 50 mm uses the above-30-to-50-mm IT range; a size just above 50 mm uses the next range. Fundamental deviations can use finer intervals.